.jpg)
Shuiyi Cyclean™ Enhanced RO Membrane Products
Shuiyi Cyclean™ Enhanced RO Membranes feature durability and stable perfor mance, making them ideal for challenging wastewater reuse applications involving high COD, high hardness and frequent cleaning requirements.
- Rugged and Durable
Clean™ material technology enables a thicker separation layer and enhanced scratch resistance, ensuring consistent permeate quality. - Anti-Fouling
Rheogood™ flow channel technology facilitates the discharge of solid contaminants, minimizing fouling during operation and enabling rapid differential pressure recovery after cleaning.
| Model | Parameter | ||
| Item | CR-8040 | CR-4040 | |
| Membrane element parameters⁽¹⁾ | Effective membrane area | 37m² | 8.4m² |
| Membrane material | Aromatic polyamide | ||
| Structure | Spiral-wound | ||
| Inlet mesh thickness | 34 mil | 28 mil | |
| Dry membrane weight | 13kg | 4kg | |
| Wet membrane weight | 15kg | 4.5kg | |
| Length | 1016mm | ||
| Diameter | 201mm | 99mm | |
| Permeate collector installation diameter | 29mm | 19mm | |
| Connection length | – | 27mm | |
| Standard test solution | 2000mg/L NaCl | ||
| Operating pressure | 1.55MPa | ||
| Test temperature | 25℃ | ||
| Recovery rate | 15% | ||
| pH | 7~8 | ||
| Water production rate⁽²⁾ | 41m³/d | 8.5m³/d | |
| Standard rejection rate | 99.6% | ||
| Membrane operational parameters | Maximum operating pressure | 4.1MPa/600 psi | |
| Maximum inlet water flow | 17m³/h | 3.6m³/h | |
| Inlet water temperature range | 5~40℃ | ||
| Inlet water pH range | 2~11 | ||
| Cleaning pH range⁽³⁾ | 1~13 | ||
| Maximum inlet water turbidity | 1.0NTU | ||
| Maximum inlet water SDI₁₅ | 5.0 | ||
| Inlet water residual chlorine | <0.1mg/L | ||
| Maximum pressure drop per element⁽⁴⁾ | 0.1MPa | ||
Note:
(1) The parameters listed are measured after 30 minutes of stable system operation;
(2) Water production rate has a deviation range of ±15%;
(3) Chemical cleaning recommended at temperatures ≤30°C, above which cleaning solution pH shall not exceed 2.0-12.0;
(4) In multi-element housings, the maximum pressure drop from inlet to outlet should be controlled within 0.25MPa, not exceeding 0.3MPa in extreme cases;
(5) RBW-HR and RBW-LE may also use the 440 high-flow and 4040 commercial membrane elements.
The data presented herein have been tested and are reliable, but variability may occur due to different testing methods and operating conditions. Therefore, usersshould combine practical application processes and thoroughly understand the products of Ningbo Shuiyi MembraneTechnology Development Co., Ltd.
Shuiyi Cyclean™ Enhanced RO Membranes are widely used in challenging wastewater reuse applications across the steel, coal chemical and petrochemical industries due to their rugged and stable performance.